1.
Rev. bras. oftalmol ; 81: e0036, 2022. tab, graf
Article in English | LILACS | ID: biblio-1376779

ABSTRACT

ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development of new protocols to evaluate, diagnose, and manage this disease.


RESUMO O objetivo deste estudo é destacar o impacto da resposta biomecânica corneana em métodos de tonometria in vivo disponíveis para o manejo do glaucoma. Trata-se de revisão sistemática de tonômetros de ar que analisa a resposta à deformação corneana, com foco especial na investigação da correlação dos parâmetros derivados com as medições da pressão intraocular. Os dois tonômetros mais recentes e comercialmente disponíveis fornecem informações promissoras sobre as características biomecânicas da córnea e sua relação com o glaucoma, permitindo o desenvolvimento de novos protocolos para avaliar, diagnosticar e controlar a doença.


Subject(s)
Humans , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Biomechanical Phenomena , Cornea/anatomy & histology , Cornea/physiology , Intraocular Pressure/physiology , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Diagnostic Techniques, Ophthalmological/instrumentation , Elasticity/physiology , Models, Theoretical
2.
Rev. latinoam. enferm. (Online) ; 27: e3141, 2019. tab
Article in Portuguese | LILACS, BDENF | ID: biblio-1004242

ABSTRACT

Objetivo identificar as principais complicações intraoperatórias dos pacientes que realizaram ceratoplastias e sua relação com fatores clínicos e cirúrgicos. Método estudo transversal, observacional. Realizou-se um censo dos pacientes submetidos a ceratoplastias que totalizou 258 procedimentos. Resultados foram registradas 22 complicações intraoperatórias, todas em ceratoplastias penetrantes. Do total, 59,09% foram realizadas em pacientes do sexo masculino com idade média de 58,5 anos. A principal complicação intraoperatória notificada foi a perda vítrea (36,36%). Encontrou-se relação estatisticamente significativa entre a variável "complicação intraoperatória" e as variáveis "cirurgia prévia", "ceratoplastia combinada com extração de catarata" e "botão corneano do receptor maior que 8,0 mm". Conclusão identificar as principais complicações intraoperatórias da ceratoplastia possibilita à enfermagem compreender quais fatores podem interferir nesses procedimentos, apontar possíveis fatores preditores das complicações e buscar medidas de controles para que tais complicações não ocorram.


Objective to identify the main intraoperative complications of patients who underwent keratoplasty and relationship between these complications and clinical and surgical factors. Method cross-sectional observational study. A census of the patients submitted to keratoplasty was carried out, which totaled 258 procedures. Results twenty-two intraoperative complications were recorded, all in penetrating keratoplasty surgeries, of which 59.09% were performed in male patients with a mean age of 58.5 years. The main intraoperative complication was vitreous loss (36.36%). A statistically significant relationship was found between the variable "intraoperative complication" and the variables "previous surgery", "combined keratoplasty and cataract extraction" and "corneal host button greater than 8.0 mm". Conclusion identifying the main intraoperative complications of keratoplasty enables nurses to understand which factors may interfere with these procedures, point out possible predictors of complications, and seek control measures so that such complications do not occur.


Objetivo identificar las principales complicaciones intraoperatorias de los pacientes que realizaron queratoplastias y su relación con factores clínicos y quirúrgicos. Método estudio transversal, observacional. Se realizó un censo de los pacientes sometidos a las queratoplastias que tuvo un total de 258 procedimientos. Resultados fueron registradas 22 complicaciones intraoperatorias, todas en queratoplastias penetrantes. Del total, 59,09% fueron realizadas en pacientes del sexo masculino con edad media de 58,5 años. La principal complicación intraoperatoria notificada fue la pérdida vítrea (36,36%). Fue encontrada relación estadísticamente significativa entre la variable "complicación intraoperatoria" y las variables "cirugía previa", "queratoplastia combinada con extracción de catarata" y "botón corneal del receptor mayor que 8,0 mm". Conclusión identificar las principales complicaciones intraoperatorias de la queratoplastia posibilita a la enfermería comprender cuáles factores pueden interferir en estos procedimientos, apuntar posibles factores predictores de las complicaciones y buscar medidas de controles para que tales complicaciones no ocurran.


Subject(s)
Humans , Corneal Transplantation/rehabilitation , Keratoplasty, Penetrating/methods , Intraoperative Complications , Cataract Extraction , Cornea/physiology , Eye/anatomy & histology
3.
Clinics ; 73: e491, 2018. tab, graf
Article in English | LILACS | ID: biblio-952791

ABSTRACT

OBJECTIVE: To evaluate the relationship of biomechanical properties, corneal hysteresis and corneal resistance factor with age, sex and various corneal parameters measured with a Pentacam in normal subjects. METHODS: A total of 226 eyes from 113 patients were enrolled in this study. The subjects underwent Ocular Response Analyzer and Pentacam evaluations. A varying-intercept multilevel regression was implemented using Bayesian inference. The predictor variables were age, sex, central corneal thickness, corneal volume at a 7-mm diameter, anterior chamber angle and volume, anterior chamber depth, mean radius of the corneal curvature and corneal astigmatism. RESULTS: Corneal hysteresis ranged from 5.5 to 14.8 mmHg (mean 10.42±1.74 mmHg), and the corneal resistance factor ranged from 5.7 to 15.5 mmHg (mean 10.23±1.88 mmHg). No predictor variable other than gender and central corneal thickness had a significant correlation with either corneal hysteresis or corneal resistance factor. Corneal hysteresis was positively associated with female sex and with central corneal thickness, and corneal resistance factor was positively associated with central corneal thickness. CONCLUSION: Despite the associations found, only a small fraction of the variance in biomechanical measurements could be explained by the descriptors that were evaluated, indicating the influence of other corneal aspects on the biomechanical characteristics.


Subject(s)
Humans , Male , Female , Cornea/physiology , Anterior Eye Segment/physiology , Tonometry, Ocular , Biomechanical Phenomena/physiology , Bayes Theorem , Cornea/anatomy & histology , Intraocular Pressure/physiology , Anterior Eye Segment/anatomy & histology
4.
Rev. bras. oftalmol ; 76(6): 275-279, nov.-dez. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-899091

ABSTRACT

Resumo Otimização por Enxame de Partículas (PSO) é uma técnica de inteligência artificial (AI), que pode ser usada para encontrar soluções aproximadas para problemas numéricos de maximização e minimização extremamente difíceis. Neste trabalho, utilizou-se um algoritmo PSO para comparar os deslocamentos sofridos por uma amostra de córnea humana submetida à uma pressão interna de 45 mmHg com resultados de simulações numéricas e identificar valores otimizados para propriedades hiperelásticas da córnea (µ e α). Por meio dos resultados das simulações via análise inversa pelo Método dos Elementos Finitos (MEF), em conjunto com o algoritmo PSO, foram encontrados valores otimizados de µ = 0,047 e α = 106,7. Quando comparado com resultados otimizados por meio de um software comercial, foram encontrados erros de aproximadamente 0,15%. Por meio dos resultados obtidos, verificou-se ainda que, variando os valores dos coeficientes de inércia da partícula no algoritmo PSO, os resultados podem sofrer ligeira melhoria, o que demonstra potencial uso do PSO em conjunto com análise inversa do MEF para caracterização de materiais hiperelásticos, utilizando modelos geométricos simplificados


Abstract Particle Swarm Optimization (PSO) is an artificial intelligence technique (AI) that can be used to find approximate solutions to numerical problems of maximization and minimization. In this study, it was used a PSO algorithm to compare displacements from human cornea sample subjected to internal pressure of 45 mmHg with Results of numerical simulations were provided which identified optimized values for hyperelastic properties of the cornea (µ and α). By means of the results from numerical simulations via inverse analysis by the Finite Element Method (FEM), in conjunction with the PSO algorithm, optimized values of µ = 0.047 and α = 106.7 were found. When compared with optimized results from commercial software, errors around 0.15% were found. Results showed that, varying the values of particle inertia coefficients in the PSO algorithm, simulated displacements have improved when compared to experimental data. This demonstrates the potential use of PSO algorithm in conjunction with the FEM inverse analysis for hyperelastic materials characterization, using simplified geometrical models


Subject(s)
Humans , Biomechanical Phenomena , Cornea/physiology , Algorithms , Computer Simulation , Cornea/anatomy & histology , Finite Element Analysis , Elastic Modulus/physiology , Models, Biological
5.
Rev. bras. oftalmol ; 76(2): 61-64, Mar.-Apr. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-899042

ABSTRACT

Resumo Objetivo: Correlacionar o coeficiente de asfericidade com a aberração esférica longitudinal na superfície corneana, correlacionando também cada uma dessas variáveis com a ceratometria média Métodos: Realizou-se um estudo observacional através da coleta de dados pré-operatórios nos prontuários de indivíduos candidatos a facectomia. Os dados coletados se referiam ao sexo e idade, além do Q, LSA da superfície corneana e ceratometria média (Km). Foram excluídos do estudo os pacientes que realizaram qualquer procedimento cirúrgico corneano, por alterar as medidas da Q, LSA e Km. O topógrafo selecionou, de maneira fixa, uma área 4,5mm da superfície anterior da córnea para medida do Q e da LSA, tendo como ponto central o eixo pupilar. A ocorrência da LSA é relevante em ambientes de penumbra, em indivíduos com pupila maior que 3mm. Resultados: A amostra foi composta por 70 olhos de 35 indivíduos: 24 (68,6%) mulheres e 11 (31,4%) homens. A idade variou de 48 a 89 anos (média de 69,97 ± 8,29). A Km variou de 41,00D a 46,50D com média de 43,94 ± 1,48D. Na avaliação do Q da superfície corneana se observou uma média de -0,15 ± 0,15. Seis (8,57%) córneas apresentaram desenho esférico com Q= 0 e apenas uma córnea apresentou desenho asférico com Q= -0,50, gerando LSA= 0,0µm. Em relação a LSA da superfície corneana se observou média de +0,33 ± 0,14 µm. Quarenta e dois olhos (60,0%) apresentaram LSA entre +0,31 a +0,64µm e 19 (27,15%) entre +0,16 a +0,30µm. Não houve correção entre a Km e o Q (r= -0,005 / p= 0,965), assim como entre Km e a LSA (r= 0,167 / p= 0,170). Observou-se correlação (r= 0,962 / p= 0,000) entre as variáveis Q x LSA. Conclusão: Foi observada correlação entre o Q e a LSA da superfície corneana. Não foi observado correlações entre o coeficiente de asfericidade ou aberração esférica longitudinal com a ceratometria média.


Abstract Objective: To correlate the asphericity coefficient (Q) with longitudinal spherical aberration (LSA) of the corneal surface, also correlating each of these variables with the average keratometry Methods: An observational study was conducted by collecting preoperative data from the medical records of individuals candidate cataract surgery, i.e., patient sex and age, as well as Q, LSA of the corneal surface and mean keratometry (Km). Patients who had been subjected to any corneal surgical procedure who would alter Q, LSA and Km measuements were excluded. The corneanl topograph selected, fixedly, a 4.5 mm area of the anterior surface of the cornea for the measurement of Q and LSA, having the pupillary axis as the central point, since the occurrence of LSA is relevant in dim environments in individuals with a pupil wider than 3 mm Results: The sample consisted of 70 eyes of 35 individuals, 24 of them women (68.6%) and 11 men (31.4%) ranging in age from 48 to 89 years (mean: 69.97 ± 8.29). Km ranged from 41.00 to 46.50 D, with a mean of 43.94 ± 1.48D, and mean Q of the corneal surface was -0.15 ± 0.15. Six corneas showed a spherical design (Q= 0.0) and only one showed an aspheric design with Q = -0.50, generating an LSA of 0.0. Mean LSA of the corneal surface was +0.33 ± 0.14 µm. Only one eye showed an LSA equal to 0.0µm, and five showed an LSA of +0.10 to +0.30µm. No eye showed a negative LSA of the corneal surface. There was no correlation between Km and Q (r = -0.005 / p = 0.965) or between Km and LSA (r = 0.167 / p = 0.170). A correlation (r = 0.962 / p = 0.000) was observed between Q and LSA Conclusion: There was a correlation between Q and LSA of the corneal surface. There was no correlation between the sphericity coefficient or longitudinal spherical aberration with the average keratometry.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Cornea/anatomy & histology , Corneal Topography/methods , Organ Size , Contrast Sensitivity , Pupil , Medical Records , Cornea/physiology , Lens Implantation, Intraocular , Observational Study , Mathematics , Ocular Physiological Phenomena
6.
Rev. bras. oftalmol ; 76(1): 43-49, Jan.-Feb. 2017. tab
Article in Portuguese | LILACS | ID: biblio-844067

ABSTRACT

RESUMO O objetivo desta revisão é de determinar as indicações e eficácia da cirurgia que promove novas ligações covalentes entre as fibras de colágeno da córnea, conhecida como Cross-Linking (CXL), assim como esclarecer seus objetivos. O ceratocone é uma doença ectasica da córnea, bilateral, assimétrica, que, principalmente, cursa com encurvamento e afinamentos progressivo, e se inicia em geral na segunda década de vida. O uso primário do CXL tem sido na interrupção da progressão do Ceratocone. Apesar do conhecido encurvamento no estroma da córnea ocorrer nesses pacientes, a fisiopatologia por trás do ceratocone ainda é desconhecida e parece ser multifatorial. Pela evidencia literária disponível até o momento, o CXL da córnea esta, portanto indicado nos pacientes com doença em progressão. Concluímos que existe evidencia suficiente para afirmar que o CXL da córnea é eficaz na estabilização da doença ectásica da cornea.


ABSTRACT The purpose of this review is to determine the indications and efficacy of the surgery that promotes new covalent bonds between the collagen fibers of the cornea, known as Cross-Linking (CXL), as well as to clarify its objectives. Keratoconus is a bilateral, asymmetric ectasic disease of the cornea that mainly courses with steepening and progressive thinning, and usually begins in the second decade of life. The primary use of CXL has been in discontinuing the progression of keratoconus. Although known corneal stromal remodeling occurs in these patients, the pathophysiology behind keratoconus is still unknown and appears to be multifactorial. By the literary evidence available to date, the CXL of the cornea is safely indicated in patients with progressing disease. We conclude that there is sufficient evidence to affirm that cornea CXL is effective in stabilizing corneal ectasic disease.


Subject(s)
Cornea/metabolism , Cornea/physiology , Cross-Linking Reagents , Keratoconus/drug therapy , Guidelines as Topic , Riboflavin/administration & dosage
7.
Rev. bras. oftalmol ; 75(3): 209-213, tab
Article in Portuguese | LILACS | ID: lil-787693

ABSTRACT

RESUMO Objetivo: Avaliar a utilidade do tonômetro de ar (TA) em estudos populacionais em indivíduos suspeitos de hipertensão ocular, comparando os valores com os fornecidos pelo tonômetro de aplanação de Goldmann (TG). Métodos: Estudo transversal, de amostra probabilística, composta por 11.452 indivíduos e"20 anos, compondo-se uma subamostra dos que apresentaram valores de pressão intraocular (PIO) obtidos com o TA e"20mmHg, nos quais a PIO foi repetida com o TG. Os resultados dos dois tonmetros foram comparados considerando sexo, cor da pele referida, lateralidade, relação escavação/disco (Â0,6; entre e"0,6 e <0,8; e"0,8) e diagnóstico. Foram consideradas três situações: não-portadores de glaucoma (NG), suspeitos (SG) e portadores de glaucoma (CG). Para comparação entre as medidas foi utilizado o teste t de Student para amostras pareadas e o teste de correlação de Pearson para avaliar a associação entre PIO, idade e tonometria. Resultados: Foram detectados 198 indivíduos (339 olhos) com PIOe"20mmHg com o TA, que tiveram a medida repetida com o TG. Foram considerados 233 olhos como NG, 47 olhos como SG e 19 olhos como CG. Em olhos com escavação e"0,8, a medida com TA e TG foram semelhantes. Nos NG e SG, o TA superestimou os valores. Houve associação entre aumento da PIO e aumento da idade com os dois tonmetros. Conclusão: Valores de PIO são superiores com TA comparados ao TG, principalmente quando a PIO é normal. Há concordância entre os métodos quando a PIO é alta e a escavação do nervo óptico é aumentada, o que valida a aplicação do TA em campanhas populacionais.


ABSTRACT Purpose: to evaluate the use of air tonometer (TA) in population studies in individuals suspected of ocular hypertension, comparing values with those provided by the Goldmann Tonometer (GT). Methods: a cross-sectional study was done using a probabilistic sample consisting of 11,452 individuals e"20 years old.A subsample composed by the individuals with IOP values obtained with TA e"20 mmHg was selected, in which IOP was repeated with the GT. The results of both tonometers were compared considering gender, referred color of skin, laterality, cup-to-disc ratio (Â0.6; e"0.6 and <0.8; e"0.8) and diagnosis, considering three situations: without glaucoma (NG), suspected glaucoma (SG) and patients with glaucoma (CG). The Student t test was used for paired samples and the Pearson correlation test to evaluate the association between IOP, age and tonometry. Results: we identified 198 individuals (339 eyes) with IOP e"20mmHg with the TA, who had the measures repeated with the GT. Two hundred and thirty-three eyes were considered as NG, 47 eyes as SG and 19 eyes as CG. In eyes with cup-to-disc ratio e"0.8, the TA and GT measurements were similar. In NG and SG, the TA overestimated values. There was an association between increased IOP and increasing age with both tonometers. Conclusion: IOP values are higher with TA compared to GT, especially when IOP is normal.There is agreement between the methods when IOP is high and the optic nerve excavation is increased, which validates the application of TA in population campaigns.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Tonometry, Ocular/statistics & numerical data , Comparative Study , Glaucoma/diagnosis , Glaucoma/epidemiology , Ocular Hypertension/diagnosis , Ocular Hypertension/epidemiology , Cross-Sectional Studies , Probability , Cornea/physiology , Observational Study , Intraocular Pressure/physiology
8.
Rev. bras. oftalmol ; 73(4): 199-201, Jul-Aug/2014.
Article in English | LILACS | ID: lil-730586

ABSTRACT

Purpose: Evaluate the magnitude of cyclotorsion during cataract surgery in patients with indication for intraocular toric lenses comparing the results after peribulbar and after topical anesthesia. Methods: This prospective study comprised 112 eyes that underwent cataract surgery with implantation of toric intraocular lens by topical anesthesia or peribulbar block. We estimated how many degrees of cyclotorsion occurred after topical anesthesia and peribulbar block with the patient in supine position. A tag was performed in the position of 180 degrees of the right eye and zero degrees of the left eye, with the patient seated. Afterwards, it was requested a change to the supine position and then a new dial in 180 and zero degrees respectively from right and left eye were made. Results: The current study demonstrated that patients submitted to cataract surgery with implantation of toriclens under local anesthesia showed approximately 6.89 degrees of incyclotorsion (82 eyes) and 6.93 degrees of excyclotorsion (38 eyes) and a mean of cyclotorsion of 6.91 degrees. Patients undergoing peribulbar block showed 5.68 degrees of incyclotorsion (73 eyes) and 4.81 degrees of excyclotorsion (47 eyes) and a mean of cyclotorsion of 4.92 degrees. Conclusion: Through the study we can see that the movement of incyclotorsion in patients undergoing peribulbar anesthesia was lower when compared to topical anesthesia. This is relevant since the greater the incyclotorsion, the lower the predictability of the surgery and the lower the chance of obtaining excellent results in the final refractometric. .


Objetivo: Avaliar a magnitude da ciclotorção durante a cirurgia de catarata em pacientes com indicação de lentes intraoculares tóricas comparando os resultados após o bloqueio peribulbar e após a anestesia tópica. Métodos: Esse estudo prospectivo compreende 112 olhos que foram submetidos à cirurgia de catarata com implante de lente intraocular tórica por meio de anestesia tópica ou bloqueio peribulbar. Foram estimados quantos graus de ciclotorção ocorreu após a anestesia tópica e após o bloqueio peribulbar, com o paciente em posição supina.Foi realizada uma marcação na posição de 180 graus do olho direito e zero grau do olho esquerdo, com o paciente sentado, em seguida,houve uma mudançade posição para decúbito dorsal, sendo realizadas novas marcações em 180 e zero graus dos olhos direito e esquerdo, respectivamente. Resultados: O presente estudo demonstrou que pacientes submetidos à facoemulsificação com implante de lente tórica com anestesia tópica apresentaram aproximadamente 6.89 graus de inciclotorção (82 olhos) e 6,93 graus de exciclotorção (38 olhos) com uma média de ciclotorção de 6.91 graus. Já os pacientes submetidos à anestesia peribulbar apresentaram 5.68 graus de inciclotorção(73 olhos) e 4,81 graus de exciclotorção (47 olhos) com uma média de ciclotorção de 4,92. Conclusão: Através do estudo podemos observar que o movimento de inciclotorção em pacientes submetidos à anestesia peribulbar foi menor quando comparado ao da anestesia tópica. Isso se torna relevante uma vez que, quanto maior for a inciclotorção, menor a previsibilidade da cirurgia e menor a chance de obtenção de excelência nos resultados refratométricos finais. .


Subject(s)
Humans , Optical Rotation , Posture , Torsion Abnormality/diagnosis , Cataract Extraction , Supine Position , Visual Acuity , Prospective Studies , Administration, Topical , Cornea/physiology , Lens Implantation, Intraocular , Eye Movements , Patient Positioning , Intraoperative Complications , Anesthesia, Local , Nerve Block
9.
Arq. bras. oftalmol ; 77(2): 84-87, Mar-Apr/2014. tab, graf
Article in English | LILACS | ID: lil-716255

ABSTRACT

Purpose: To evaluate changes in corneal sensitivity following corneal cross-linking (CXL) in patients with progressive earlier stage keratoconus. Methods: Thirty-eight eyes of 19 patients (11 women, 8 men) were included in a prospective, nonrandomized clinical study. The mean patient age was 22 years (range, 18-26 years). Inclusion criteria were early stage bilateral progressive keratoconus, a transparent cornea, and a thickness of ≥440 µm in the thinnest area of the cornea. Using the Cochet-Bonnet esthesiometer, central corneal sensitivity was measured before surgery, 7 days after surgery, and once a month thereafter until recovery of baseline preoperative levels. Central corneal sensitivity >40 mm was considered normal. Results: Corneal sensitivity gradually returned to preoperative levels in all treated eyes. The mean central corneal sensitivity was 52.2, 24.0, 38.2, 42.5, 50.0, and 52.5 mm before surgery, 7 days after surgery, and at 1, 2, 3, and 4 months after surgery, respectively. Normal levels of corneal sensation, but not baseline (preoperative) levels, were observed 2 months after surgery. The preoperative levels were observed 3 months after surgery. Conclusions: Our results suggest that central corneal sensitivity can be decreased for as long as 3 months after CXL for progressive earlier stage keratoconus. .


Objetivo: Avaliar as alterações da sensibilidade corneana após cross-linking (CXL) da córnea em pacientes com ceratocone progressivo em estágio inicial. Métodos: Trinta e oito olhos de 19 pacientes (11 mulheres, 8 homens) foram incluídos em um estudo clínico prospectivo, não randomizado. A média de idade dos pacientes era de 22 anos (variação, 18-26 anos). Os critérios de inclusão foram ceratocone progressivo bilateral em estágio inicial, córnea transparente e espessura da córnea ≥440 µm usando o estesiômetro de Cochet-Bonnet, mediu-se a sensibilidade da córnea no pré-operatório, após 7 dias, e uma vez por mês até a recuperação dos níveis pré-operatórios. Foram considerados normais, valores de sensibilidade corneana superiores a 40 mm. Resultados: A sensibilidade da córnea retornou gradualmente aos níveis pré-operatórios em todos os olhos tratados. A média de sensibilidade corneana central foi de 52,2, 24,0, 38,2, 42,5, 50,0 e 52,5 mm, antes da cirurgia, aos 7 dias, e em 1, 2, 3 e 4 meses após a cirurgia, respectivamente. Níveis normais de sensibilidade, mas não os níveis pré-operatórios basais, foram observados dois meses após a cirurgia. Níveis pré-operatórios foram observados três meses após a cirurgia. Conclusão: Nossos resultados sugerem que após CXL para ceratocone progressivo em estágio inicial, a sensibilidade corneana permanece diminuída por até 3 meses. .


Subject(s)
Adolescent , Adult , Female , Humans , Male , Young Adult , Cornea/physiology , Cross-Linking Reagents/therapeutic use , Epithelium, Corneal/surgery , Keratoconus/therapy , Photosensitizing Agents/therapeutic use , Riboflavin/therapeutic use , Disease Progression , Follow-Up Studies , Keratoconus/physiopathology , Prospective Studies , Treatment Outcome , Ultraviolet Rays , Visual Acuity
10.
Arq. bras. oftalmol ; 77(1): 60-65, Jan-Feb/2014. graf
Article in English | LILACS | ID: lil-715559

ABSTRACT

The cornea is a transparent tissue in front of the eye that refracts light and facilitates vision. A slight change in the geometry of the cornea remarkably affects the optical power. Because of this sensitivity, biomechanical study of the cornea can reveal much about its performance and function. In vivo and in vitro studies have been conducted to investigate the mechanics of the cornea and determine its characteristics. Numerical techniques such as the finite element method (FEM) have been extensively implemented as effective and noninvasive methods for analyzing corneal mechanics and possible disorders. This article reviews the use of FEM for assessing the mechanical behavior of the cornea. Different applications of FEM in corneal disease studies, surgical predictions, impact simulations, and clinical applications have been reviewed. Some suggestions for the future of this type of modeling in the area of corneal mechanics are also discussed.


A córnea é um tecido transparente na parte frontal do olho, que refrata a luz e torna a visão possível. Uma ligeira alteração na geometria da córnea notavelmente afeta a sua potência óptica. Devido a essa sensibilidade, o estudo biomecânico da córnea pode revelar muito sobre o seu desempenho e funcionalidade. Estudos in vivo e in vitro foram realizados para investigar a mecânica da córnea e para determinar suas características. Técnicas numéricas como o método dos elementos finitos (FEM) foram amplamente implementadas como métodos eficazes e não invasivos de análise mecânica da córnea e seus possíveis transtornos. Este artigo analisa o uso de FEM para avaliar o comportamento mecânico da córnea. Diferentes aplicações da FEM no estudo de doenças da córnea, previsões cirúrgicas, simulações de impacto e aplicações clínicas foram revistos. São discutidas algumas sugestões para o futuro deste tipo de modelagem na área de mecânica de córnea.


Subject(s)
Humans , Corneal Topography , Cornea/physiology , Finite Element Analysis , Cornea/anatomy & histology , Surface Properties
11.
Rev. bras. oftalmol ; 73(1): 37-39, Jan-Feb/2014. graf
Article in Portuguese | LILACS | ID: lil-712760

ABSTRACT

Relato de caso de uma paciente, com córnea espessa, por distrofia de Fuchs em fase inicial, ainda com transparência corneana preservada (edema corneano subclínico), associado à pressão intraocular (PIO) normal por tonometria de aplanação de Goldman (TAG), que teve entretanto, o diagnóstico de glaucoma primário de ângulo aberto com base em alterações estruturais do nervo óptico. O estudo tomográfico demonstrou padrão de paquimetria espacial compatível com edema subclínico. O estudo biomecânico da córnea com o ORA (Ocular Response Analyzer, ® Reichert), associado à medida corrigida da PIO, possibilitou o entendimento da influência da córnea, que apesar de mais espessa, levava a uma TAG falsamente reduzida (hipoestimada). O estudo da PIO com sistema de tonografia digital de contorno (PASCAL) corroborou com os achados do ORA. Este exemplo ressalta a importância de novas tecnologias na avaliação de pacientes com suspeita de glaucoma, e destaca que a correção da TAG, com base em algoritmos lineares relacionados com a paquimetria central apenas, pode determinar sérios erros de interpretação clínica.


Case report of a patient, with a thick cornea, for Fuchs dystrophy in its early stages, yet with preserved corneal transparency (subclinical corneal edema), associated with normal intraocular pressure (IOP) by Goldman applanation tonometry (GAT), which was however, the diagnosis of primary open-angle glaucoma on the basis of structural changes of the optic nerve. The tomographic study showed a pattern of spatial pachymetry compatible with subclinical edema. The corneal biomechanical study with ORA (Ocular Response Analyzer, Reichert ®) associated with corrected IOP measurement, allowed the understanding of the corneal influence, which, although thicker, leading to a falsely low TAG (underestimated). The IOP study with tonography system digital (PASCAL) corroborated with the findings of ORA. This example highlights the importance of new technologies in patients' evaluation with suspected glaucoma, and highlights that the correction of TAG, based on linear algorithms related to central corneal thickness alone, can determine serious errors in clinical interpretation.


Subject(s)
Humans , Female , Middle Aged , Tonometry, Ocular/methods , Biomechanical Phenomena , Cornea/physiology , Cornea/pathology , Corneal Pachymetry/methods , Intraocular Pressure/physiology , Optic Nerve/pathology , Tonometry, Ocular/instrumentation , Tomography , Fuchs' Endothelial Dystrophy/physiopathology , Glaucoma, Open-Angle/diagnosis , Ocular Hypertension/diagnosis , Slit Lamp Microscopy , Gonioscopy
12.
Arq. bras. oftalmol ; 76(5): 278-281, set.-out. 2013. ilus, tab
Article in English | LILACS | ID: lil-690604

ABSTRACT

PURPOSE: To study the deformation response of three distinct contact lenses with known structures, which served as corneal models, under different chamber pressures using ultra-high-speed (UHS) Scheimpflug imaging. METHODS: Three hydrophilic contact lenses were mounted on a sealed water chamber with precisely adjustable pressure: TAN-G5X (41% hydroxyethylmethacrylate/glycolmethacrylate, 550 µm thick), TAN-40 (62% hydroxyethylmethacrylate, 525 µm thick) and TAN-58 (42% methylmethacrylate, 258 µm thick). Each model was tested five times under different pressures (5, 15, 25, 35 and 45 mmHg), using ultra-high-speed Scheimpflug imaging during non-contact tonometry. 140 Scheimpflug images were taken with the UHS camera in each measurement. The deformation amplitude during non-contact tonometry was determined as the highest displacement of the apex at the highest concavity (HC) moment. RESULTS: At each pressure level, the deformation amplitude was statistically different for each lens tested (p<0.001, ANOVA). Each lens had different deformation amplitudes under different pressure levels (p<0.001; Bonferroni post-hoc test). The thicker lens with less polymer (TAN-G5X) had a higher deformation (less stiff behavior) than the one that was thinner but with more polymer (TAN-40), when measured at the same internal pressure. The thinnest lens with less polymers (TAN-58) had a lower deformation amplitude (stiffer behavior) at higher pressures than the thicker ones with more polymer (TAN-40 and TAN-G5X) at lower pressures. CONCLUSIONS: UHS Scheimpflug imaging allowed for biomechanical assessment through deformation characterization of corneal models. Biomechanical behavior was more influenced by material composition than by thickness. Chamber pressure had a significant impact on deformation response of each lens.


OBJETIVO: Estudar a resposta de deformação de três lentes de contato com estruturas conhecidas, que serviram como modelos de córnea, recorrendo à imagem de Scheimpflug de alta velocidade. MÉTODOS: Três lentes de contato hidrófilas foram montadas em uma câmara de água selada com pressão ajustável: TAN-G5X (41% hidroxietilmetacrilato/glycolmethacrylate, 550µm de espessura), TAN-40 (hidroxietilmetacrilato 62%, 525 µm de espessura) e TAN-58 (42% metilmetacrilato, 258 µm de espessura). Cada modelo foi testado cinco vezes sob pressões diferentes (5, 15, 25, 35 e 45 mmHg), recorrendo a um tonómetro de não-contato acoplado a uma câmara de Scheimpflug de alta velocidade. Cento e quarenta imagens de Scheimpflug foram capturadas em cada medição. A amplitude de deformação foi determinada como o maior deslocamento do ápice no momento de maior concavidade do modelo testado. RESULTADOS: Em cada nível de pressão, a amplitude de deformação foi estatisticamente diferente para cada lente testada (p<0,001, ANOVA). Cada lente teve amplitude de deformação diferente sob distintos níveis de pressão (p<0,001; Bonferroni teste post-hoc). A lente mais espessa e com menos polímero (TAN-G5X) apresentou maior deformação (comportamento menos rígido) do que aquela que era mais fina mas com mais polímero (TAN-40), quando testadas sob a mesma pressão. A lente mais fina e com menos polímero (TAN-58) apresentou uma menor amplitude de deformação (comportamento mais rígido) sob pressões mais elevadas, em comparação com as lentes mais grossas e com mais polímero (TAN-40 e TAN-G5X) em pressões mais baixas. CONCLUSÕES: A imagem de Scheimpflug de alta velocidade permite uma avaliação biomecânica através da medição da amplitude de deformação dos modelos de córnea. O comportamento biomecânico foi mais influenciado pela composição do que pela espessura da lente. A pressão da câmara apresentou um impacto significativo sobre a amplitude de deformação de cada lente.


Subject(s)
Air Pressure , Contact Lenses/standards , Cornea/physiology , Image Processing, Computer-Assisted/methods , Models, Biological , Analysis of Variance , Biomechanical Phenomena , Cornea/surgery , Corneal Pachymetry/methods , Manometry/methods
13.
Arq. bras. oftalmol ; 76(2): 111-117, mar.-abr. 2013. ilus, tab
Article in English | LILACS | ID: lil-678177

ABSTRACT

PURPOSE: To evaluate the ability of the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) to distinguish between normal and keratoconic eyes, by comparing pressure and waveform signal-derived parameters. METHODS: This retrospective comparative case series study included 112 patients with normal corneas and 41 patients with bilateral keratoconic eyes. One eye from each subject was randomly selected for analysis. Keratoconus diagnosis was based on clinical examinations, including Placido disk-based corneal topography and rotating Scheimpflug corneal tomography. Data from the ORA best waveform score (WS) measurements were extracted using ORA software. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldman-correlated intraocular pressure (IOPg), cornea-compensated intraocular pressure (IOPcc), and 37 parameters derived from the waveform signal were analyzed. Differences in the distributions among the groups were assessed using the Mann-Whitney test. Receiver operating characteristic (ROC) curves were calculated. RESULTS: Statistically significant differences between keratoconic and normal eyes were found in all parameters (p<0.05) except IOPcc and W1. The area under the ROC curve (AUROC) was greater than 0.85 for 11 parameters, including CH (0.852) and CRF (0.895). The parameters related to the area under the waveform peak during the second and first applanations (p2area and p1area) had the best performances, with AUROCs of 0.939 and 0.929, respectively. The AUROCs for CRF, p2area, and p1area were significantly greater than that for CH. CONCLUSION: There are significant differences in biomechanical metrics between normal and keratoconic eyes. Compared with the pressure-derived parameters, corneal hysteresis and corneal resistance factor, novel waveform-derived ORA parameters provide better identification of keratoconus.


OBJETIVO: Avaliar a capacidade do Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) em discriminar olhos com ceratocone de olhos normais e comparar parâmetros derivados da pressão dos parâmetros derivados da forma da curva. MÉTODOS:Estudo comparativo retrospectivo série de casos que incluiu 112 pacientes com olhos normais e 41 pacientes com ceratocone bilateral. Um olho de cada indivíduo foi randomicamente selecionado para análise. O diagnóstico de ceratocone foi baseado em exame clínico, incluindo topografia de Plácido e tomografia Scheimpflug. Informação do melhor waveform score foi extraída do software do ORA. Histerese corneana (CH), fator de resistência corneana (CRF), pressão intraocular correlacionada com Goldman (IOPg), pressão intraocular compensada pela córnea (IOPcc) e 37 novos parâmetros derivados da forma da curva do sinal do ORA foram analisados. Diferenças nas distribuições dos grupos foram avaliadas pelo teste Mann-Whitney. Curvas ROC foram calculadas. RESULTADOS: Diferenças estatisticamente significantes foram encontradas entre os olhos normais e ceratocones em todos os parâmetros (p<0,05) salvo IOPcc e W1. A área sob a curva ROC (AUROC) foi maior que 0.85 em 11 parâmetros, incluindo CH (0,852) a CRF (0,895). Os parâmetros relacionados com a área sob o pico da forma de onda durante a segunda e primeira aplanação (p2area e p1area) obtiveram as melhores performances, com AUROCs de 0,939 e 0,929, respectivamente. Os valores de AUROCs do fator de resistência corneana, p2area e p1area foram significativamente maiores que os valores de histerese corneana. CONCLUSÃO: Existem diferenças significantes nas medidas biomecânicas entre olhos normais e com ceratocone. Comparados com os parâmetros derivados da pressão, histerese corneana e fator de resistência corneana, os parâmetros derivados da forma da curva proporcionaram melhor identificação dos ceratocones.


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Middle Aged , Young Adult , Cornea/physiology , Intraocular Pressure/physiology , Keratoconus/diagnosis , Biomechanical Phenomena , Case-Control Studies , Corneal Topography , Cornea/surgery , Keratoconus/physiopathology , Keratoconus/surgery , Refractive Surgical Procedures , Retrospective Studies , Software
14.
Braz. j. med. biol. res ; 46(3): 257-262, 15/mar. 2013. tab, graf
Article in English | LILACS | ID: lil-670906

ABSTRACT

We compared two electroretinography (ERG) electrodes in dogs using ERG standards of the International Society for Clinical Electrophysiology of Vision (ISCEV). Ten healthy Yorkshire terrier dogs (mean age, 2.80 ± 1.42 years; 6 females) weighing 5.20 ± 1.56 kg were evaluated using an ERG system for veterinary use. Dark- and light-adapted ERG responses were recorded using an ERG-Jet electrode and a fiber electrode prototype. The examinations were performed during 2 visits, 3 weeks apart. Both electrodes (ERG-Jet or fiber prototype) were used on each animal and the first eye to be recorded (OD × OS) was selected randomly. Three weeks later the examination was repeated on the same animal switching the type of electrode to be used that day and the first eye to be examined. The magnitude and waveform quality obtained with the two electrode types were similar for all ERG responses. ERG amplitudes and implicit times obtained from dogs using the fiber electrode prototype were comparable to those obtained with the ERG-Jet electrode for rod, maximal rod-cone summed, cone, and 30-Hz flicker responses. The fiber electrode prototype is a low-cost device, available as an alternative instrument for clinical veterinary ERG recording for retinal function assessment.


Subject(s)
Animals , Dogs , Female , Male , Cornea/physiology , Electrodes , Electroretinography/veterinary , Equipment Design , Electroretinography/instrumentation , Electroretinography/methods , Photic Stimulation , Reproducibility of Results
15.
Rev. bras. oftalmol ; 71(5): 317-321, set.-out. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-654992

ABSTRACT

OBJETIVO: Avaliar e comparar as alterações biomecânicas da córnea por meio do Ocular Response Analyzer® (ORA Reichert Ophtalmics Instruments, Buffalo, New York, USA) antes e após Lasik com Moriá ® Sub Bowman Keratomileusis (SBK) One Use Plus (OUP) em pacientes míopes e hipermetrópes. MÉTODOS: Foram estudados 33 olhos, sendo 19 olhos míopes e 14 olhos hipermetrópes submetidos à cirurgia refrativa com técnica Lasik com flap fino (100 µ) utilizando Moriá SBK OUP. O ORA foi realizado no pré-operatório e 1 mês após a cirurgia para avaliar a biomecânica da córnea. O CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (goldmann gold standard, Goldmann correlated intraocular pressure) a IOPcc (corneal compensated intraocular pressure) e mais 38 variáveis biomecânicas da córnea derivadas do sinal de resposta foram avaliados. O Teste de Kolmogorov-Smirnov foi utilizado para avaliar a distribuição normal. O teste de Wilcoxon foi utilizado para comparar as variáveis antes e após a cirurgia para cada grupo. As diferenças entre as medidas pré e pós-operatórias dos olhos míopes foram comparadas com as diferenças obtidas nos olhos hipermetrópes, utilizando-se o teste de Mann-Whitney. Foi considerado como estatisticamente significante p < 0,05%. RESULTADOS: Houve diferença significativa antes e após Lasik em olhos míopes e hipermetrópes na variável IOPg(Wilcoxon, p <0,05), porém não houve em IOPcc. Somente em olhos míopes houve diferenças significativas em CH e CRF, antes e após Lasik com Moriá SBK OUP, como também 9 parâmetros derivados do ORA Waveform_Sinal Gráfico (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p <0,05). Em olhos hipermetrópes houve diferenças antes e após Lasik das seguintes variáveis: aspect2, h2, dive2, mslew2 e H21 (Wilcoxon p<0,05).Diferenças nas variáveis IOPg e p1area, antes e após Lasik foram maiores em olhos míopes do que hipermetrópes (Mann-Whitey, p <0.05). CONCLUSÃO: Existem alterações das propriedades biomecânicas da córnea após Lasik com Moriá SBK OUP. Em geral, o impacto da biomecânica da córnea após Lasik em olhos míopes é maior do que em olhos hipermetrópes. As mudanças das variáveis relacionadas ao primeiro pico de aplanação (ORA waveform) são mais vistos em olhos míopes e as relacionadas ao segundo pico de aplanação em olhos hipermetrópes.


PURPOSE: To evaluate biomechanical changes measured with the ORA (Ocular Response Analyzer®; Reichert Ophthalmic Instruments, Buffalo, New York, USA) after Lasik with the Moria One Use Plus and to compare the biomechanics changes after myopic and hyperopic ablations. METHODS: Fourteeneyes for hyperopia (H) and 19 eyes for myopia (M) were evaluated with the ORA preoperatively and 1 month after Lasik with thin flap (100 microns) using SBK-OUP (Sub-Bowman Keratomileusis - One Use Plus, Moria®).CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (gold-standard, Goldmann correlated Intraocular pressure), IOPcc (Corneal compensated Intraocular pressure) and more 38 variables derived from the corneal biomechanical response signal of the ORA were analyzed. The Wilcoxon test was used to assess differences between the variables before and after surgery for each group and the differences between the pre and postoperative (1 month) myopic eyes were compared with those obtained in hyperopic eyes, using the Mann-Whitney test. RESULTS: There was a significant difference before and after Lasik in myopic and hyperopic eyes in IOPg (Wilcoxon, p <0.05), but not in IOPcc. Only myopic eyes showed a significant difference in CH and CRF measurements before and after LASIK, as well as 9 other biomechanical parameters (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p <0, 05), 8 of these being related to the first sign of flattening.Five parameters related to the sign of the second applanation showed significant variation only in the eyes before and after hyperopic Lasik (aspect2, h2, dive2, mslew2 and H21; Wilcoxon, p<0,05).There was a difference in both myopic and hyperopic on three parameters related to the applanation signal areas (p1area, and p2area p2area1; Wilcoxon, p <0.05). Differences in IOPg and p1area, before and after surgery were significantly higher in myopic eyes than in hyperopic eyes (Mann-Whitey, p <0.05). CONCLUSION: There are several significant differences in biomechanical parameters after Lasik with Moria OUP_SBK. Overall, the impact of myopic LASIK on corneal biomechanics is higher than of hyperopic Lasik. The parameters derived from the first sign of the ORA are more affected in myopic LASIK, whereas parameters derived from the second applanation are more affected in hyperopic LASIK.


Subject(s)
Humans , Cornea/physiology , Diagnostic Techniques, Ophthalmological , Hyperopia/surgery , Keratomileusis, Laser In Situ , Myopia/surgery , Biomechanical Phenomena/physiology , Observational Studies as Topic , Prospective Studies
16.
Article in English | IMSEAR | ID: sea-145739

ABSTRACT

Determination of ‘time elapsed since death’ (TSD) is one of the important content of the post-mortem report. Although the status of transparency of cornea is variable, depending on different factors like other parameters used for the purpose of determination of time since death but it is less variable as compared to others. The study sample comprised of 238 medico-legal autopsies conducted in the department of Forensic Medicine & Toxicology, Rajendra Institute of Medical Sciences, Ranchi, Jharkhand during June 2006 to September 2007. In majority of cases cornea remains transparent & moist in 0—06 Hrs and becomes transparent & dry in 06—12 Hrs, transparent to hazy in 12—24 Hrs, hazy to opaque in 24—36 hrs and opaque in >36 Hrs. In sequence, changes occurs more in warm & moist weather then in warm & dry weather and cold & moist weather respectively and least in cold and dry weather.


Subject(s)
Autopsy/legislation & jurisprudence , Autopsy/methods , Cold Temperature , Cornea/physiology , Death , Hot Temperature , Humans , India , Postmortem Changes , Temperature , Time Factors , Weather
17.
Rev. bras. oftalmol ; 71(2): 89-99, mar.-abr. 2012. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-626582

ABSTRACT

OBJETIVO: Verificar os resultados da cirurgia de implante de segmentos de anel estromal para ceratocone e as possíveis correlações existentes entre o resultado cirúrgico e o estado biomecânico da córnea no pré-operatório. MÉTODOS: Dezenove olhos de 19 pacientes com ceratocone foram avaliados antes e 12 meses após a cirurgia de implante de segmento anel estromal. O implante de um ou dois segmentos de anel de Ferrara foi realizado de acordo com o nomograma, considerando-se espessura da córnea, padrão topográfico da ectasia e o astigmatismo. O teste de Wilcoxon signed rank foi realizado para verificar diferenças entre a acuidade visual (logMAR) corrigida com óculos antes da cirurgia (AVccPré) e a obtida sem correção (AVscPós) e com correção (AVccPós) após a cirurgia, bem como entre os valores pré e pós-operatórios de variáveis tomográficas medidas com o Pentacam e variáveis biomecânicas da córnea medidas com o ORA (ocular response analyzer). As diferenças absolutas antes e após a cirurgia (valores delta - Δ) das variáveis com diferenças significantes foram calculadas. Os valores Δ foram correlacionados com as medidas do ORA no pré-operatório por meio dos testes de Pearson ou de Spaerman, de acordo com a distribuição das variáveis ser normal ou não (teste de Kolmogorov-Smirnov). RESULTADOS: Observou-se melhora significante na AVcc, bem como na AVscPós em comparação com a AVccPré (teste de Wilcoxon, p<0,05). Houve redução significativa do astigmatismo ceratométrico (AST), dos valores ceratométricos centrais (K1 e K2), do valor ceratométrico mais elevado (KMáx) e dos índices CKI (índice de severidade do ceratocone - center keratoconus index ), IHD (índice de descentração da elevação - index of height decentration) e ISV (índice de variação da superfície - index of surface variance) após a cirurgia (teste de Wilcoxon, p<0,05). Observou-se um significativo aumento da espessura corneana a 3,8 e a 4mm do ápice em direção temporal no meridiano horizontal, bem como houve deslocamento inferior significativo da posição do KMáx (teste de Wilcoxon, p<0,05). Nenhuma variável biomecânica apresentou diferença estatisticamente significante após a cirurgia (teste de Wilcoxon, p>0,05). Os parâmetros do ORA derivados das pressões de aplanamento: histerese da córnea (corneal hysteresis - CH), fator de resistência da córnea (corneal resistance factor - CRF) e as medidas da pressão ocular (IOPg e IOPcc) não apresentaram correlações significantes com os parâmetros delta (Δ). Quinze das 38 variáveis biomecânicas derivadas do sinal de reflexo da córnea do ORA apresentaram correlação significante com pelo menos um parâmetro Δ, destacando-se as correlações entre o ΔKMáx com aindex e path1 (teste de Pearson, p<0,05; r=-0,56 e 0,56 respectivamente) e entre o ΔAVccPré-AVscPós e aindex (teste de Pearson, p<0,05; r=0,48). A variável que teve maior número de correlações significantes foi w21, que se correlacionou negativamente com ΔK2, ΔK1, ΔCKI e ΔKMáx (teste de Spearman, p<0,05; r=-0,56; -0,55; -0,51 e -0,47) respectivamente. CONCLUSÃO: Existe melhora significante da acuidade visual e de parâmetros ceratométricos após cirurgia de implante de segmentos de anel de Ferrara para ceratocone. A melhora de diversos destes parâmetros com a cirurgia foi significativamente correlacionada com características biomecânicas derivadas do sinal do reflexo da córnea do ORA no pré-operatório. Um estado biomecânico pré-operatório "mais fraco" ou "menos resistente" foi significativamente relacionado com um maior benefício clínico da cirurgia. Análises com associações múltiplas (multivariadas) são necessárias, incluindo parâmetros tomográficos da córnea e de aberrometria total do pré-operatório. Tais informações abrem novos horizontes para a seleção de pacientes e o planejamento de cirurgia de implante de segmentos de anel para ceratocone.


OBJECTIVE: To verify possible correlations between the biomechanical state of the cornea before surgery and the results of stromal ring segments implant for keratoconus. METHODS: Nineteen eyes of 19 patients with keratoconus were evaluated before and 12 months after stromal ring segment implant surgery. The implant of one or two Ferrara ring segments was performed accordingly to the nomogram, considering corneal thickness, ectasy pattern on topography and astigmatism. The Wilcoxon test was performed to verify the differences between visual acuity (logMAR) with correction before surgery (AVccPre) and without correction (AVscPos) and with correction (AVccPos) after surgery, topography variables measured with Pentacam on pre and post operative and corneal biomechanics variables measure with ORA (ocular response analyzer). The absolute differences before and after the surgery (delta values - Δ) of variables with significant differences were calculated. The Δ values were correlated with the ORA measurements pre-operatively using Pearson or Spearman's tests, according with the distribution of the variables to be or not normal (Kolmogorov-Smirnov test). RESULTS: There were significant improvements on AVcc and AVscPos comparing with AVccPre (Wilcoxon test, p<0,05). Significant reduction was observed on keratometric astigmatism (AST), Keratometric central values (K1 and K2), higher keratometric value (KMax) and topometric indices: CKI (Center Keratoconus Index), IHD (Index of Height Decentration) and ISV (Index of Surface Variance) after surgery (Wilcoxon test, p<0.05). There was a significant increase in corneal thickness of 3.8 and 4 mm from the apex toward the temporal horizontal meridian observed a significant increase on cornea thickness, and there was significant downward displacement of the position of KMax (Wilcoxon test, p<0.05). No variable biomechanical statistically significant difference after surgery (Wilcoxon test, p>0.05). The ORA parameters derivate form the aplanation pressure: Corneal Hysteresis (CH), Corneal Resistance Factor (CRF) and the measures of the ocular pressure (IOPg and IOPcc) showed no significant correlations with the parameters delta (Δ). Fifteen of the 38 biomechanical variables derived from the sign of ORA corneal reflex presented significant correlation with at least one parameter Δ, highlighting the correlations between ΔKMax with aindex e path1 (Pearson test, p<0.05; r=-0.56 and 0.56 respectively) and between AVccPre-AVscPos and aindex (Pearson test, p<0.05; r=0.48). The variable that had the greatest number of significant correlations was w21, which correlated negatively with, ΔK2, ΔK1, ΔCKI and ΔKMax (Spearman test, p<0.05; r=-0.56; -0.55; -0.51 and -0.47) respectively. CONCLUSION: There is a significant improvement in visual acuity and keratometric parameters after surgery of implant the Ferrara ring segments for keratoconus. The improvement of several of these parameters with the surgery was significantly correlated with biomechanical characteristics derived from the signal of the ORA corneal reflex preoperatively. A biomechanical preoperative state "weaker" or "less resistant" was significantly related to greater clinical benefit of surgery. Analysis with multiple associations (multivariate) is necessary, including topographic parameters of the cornea and wavefront analysis of preoperative total. This information opens up new horizons for patient selection and planning of ring segments implant surgery for keratoconus.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Prostheses and Implants , Cornea/physiology , Corneal Stroma/surgery , Prosthesis Implantation/methods , Keratoconus/surgery , Biomechanical Phenomena , Visual Acuity , Retrospective Studies , Treatment Outcome , Corneal Stroma/physiopathology , Corneal Topography , Elasticity/physiology , Preoperative Period , Corneal Pachymetry , Intraocular Pressure
18.
Rev. bras. oftalmol ; 70(4): 235-237, jul.-ago. 2011. ilus, tab
Article in English | LILACS | ID: lil-601022

ABSTRACT

PURPOSE: To demonstrate the corneal magnification using trypan blue in cataract surgery. METHODS: Eight eyes of eight patients undergoing phacoemulsification with an intraocular lens implantation were enrolled in this study. After staining the anterior capsule with Trypan Blue 0.1 percent and performing the capsulorhexis, the excised anterior capsule was placed on the corneal surface. By observing and measuring the relationship between the border of the excised anterior capsule and the intracameral capsulorhexis opening, the effect of corneal magnification was clearly demonstrated and calculated by linear method. RESULTS: The average magnification of the cornea was 20.88 percent using linear method with an average area magnification of 47.53 percent. CONCLUSION: The capsulorhexis stained by trypan blue is useful to demonstrate the magnification provided by the cornea helping to design an intended opening size.


OBJETIVO: Demonstrar a magnificação corneana utilizando o azul de tripan na cirurgia de catarata. MÉTODOS: Oito olhos de oito pacientes submetidos à facoemulsificação com implante de lente intraocular foram envolvidos neste estudo. Após corar a cápsula anterior do cristalino com azul de tripan 0,1 por cento e realizar a capsulotomia circular contínua, a cápsula excisada foi colocada sobre a superfície corneana. Após observar e aferir a relação entre a borda da cápsula anterior excisada e a abertura da cápsula intracameral, o efeito da magnificação corneana foi claramente demonstrada e calculada através do método linear. RESULTADOS: A média estimada da magnificação corneana foi de 20,88 por cento com uma média de magnificação de área de 47,53 por cento. CONCLUSÃO: A capsulorrexis corada pelo azul de tripan é útil na demonstração da magnificação corneana, auxiliando assim na correta confecção do seu tamanho.


Subject(s)
Humans , Staining and Labeling/methods , Trypan Blue , Phacoemulsification/methods , Cornea/physiology , Capsulorhexis/methods , Coloring Agents , Photography , Lens Implantation, Intraocular/methods , Corneal Pachymetry , Lens Capsule, Crystalline/anatomy & histology , Lens Capsule, Crystalline/surgery , Lenses, Intraocular
19.
Arq. bras. oftalmol ; 74(1): 13-16, Jan.-Feb. 2011. graf, tab
Article in English | LILACS | ID: lil-589931

ABSTRACT

PURPOSE: To evaluate and compare corneal hysteresis (CH) and corneal resistance factor (CRF) in healthy eyes with a central corneal thickness (CCT) < 505 µm with CH and CRF in gender-, age-, and CCT-matched keratoconus cases, and to estimate the sensitivity and specificity of these parameters for discriminating between the two groups. METHODS: Prospective, comparative case series. In total 46 eyes from 30 healthy patients with CCT < 505 µm, and 42 eyes from 30 CCT-, gender- and age-matched keratoconus cases were enrolled. Biomechanical metrics (CH and CRF) were measured using the Ocular Response Analyzer (ORA) and then compared. A receiver operating characteristic (ROC) curve was used to identify cut-off points to maximize the sensitivity and specificity for discriminating between the groups. RESULTS: The CCT was 485.96 ± 17.61 µm (range, 438 - 505) in healthy thin corneas and 483.64 ± 16.19 µm (range, 452 - 505) in keratoconus; p=0.5225. CH was 8.63 ± 1.23 mmHg (range, 5.95 - 12.2) and 8.07 ± 1.17 mmHg (range, 4.9 - 9.85), respectively; p=0.0312. CRF was 8.43 ± 1.29 mmHg (range, 5.45 - 11.10) and 7.22 ± 1.34 mmHg (range, 4.7 - 9.45), respectively; p<0.001. ROC curve analysis showed a poor overall predictive accuracy of CH (cut-off, 8.95 mmHg; sensitivity, 63 percent; specificity, 23.8 percent; test accuracy, 44.30 percent) and CRF (cut-off, 7.4 mmHg; sensitivity, 28.3 percent; specificity, 40.5 percent; test accuracy, 34.12 percent) for detecting keratoconus in the eyes studied. CONCLUSION: CH and CRF were statistically lower in keratoconus than in healthy thin corneas. However, CH and CRF offered very low sensitivity and specificity for discriminating the groups.


OBJETIVO: Avaliar e comparar a histerese corneana (CH) e o fator de resistência corneano (CRF) em olhos saudáveis com espessura corneana central (CCT) < 505 µm com os resultados de CH e CRF em pacientes com ceratocone pareados por sexo, idade e CCT, além de estimar a sensibilidade e especificidade destes parâmetros na diferenciação dos grupos. MÉTODOS: Estudo prospectivo, do tipo série de casos comparativa. No total, 46 olhos de 30 pacientes saudáveis com CCT < 505 µm, e 42 olhos de 30 pacientes com ceratocone pareados por sexo, idade e CCT foram incluídos. Os parâmetros biomecânicos (CH e CRF) foram obtidos através do equipamento Ocular Response Analyzer (ORA) e depois comparados. Curvas ROC (Receiver operating characteristic) foram utilizadas para identificar o melhor valor de corte que apresentasse a maior sensibilidade e especificidade na discriminação entre ceratocone e córneas finas saudáveis para cada dado estudado. RESULTADOS: A CCT encontrada foi 485,96 ± 17,61 µm (de 438 a 505) no grupo de córneas finas saudáveis e 483.64 ± 16,19 µm (de 452 a 505) no grupo ceratocone; p=0,5225. CH 8,63 ± 1,23 mmHg (de 5,95 a 12,2) e 8,07 ± 1,17 mmHg (de 4,9 a 9,85), respectivamente; p=0,0312. CRF 8,43 ± 1,29 mmHg (de 5,45 a 11,10) e 7,22 ± 1,34 mmHg (de 4,7 a 9,45), respectivamente; p<0,001. Análise das curvas ROC mostrou baixa acurácia na diferenciação das córneas finas saudáveis daquelas com ceratocone tanto para CH (ponto de corte, 8,95 mmHg; sensibilidade, 63 por cento; especificidade, 23,8 por cento; acurácia, 44,30 por cento) quanto para CRF (ponto de corte, 7,4 mmHg; sensibilidade, 28,3 por cento; especificidade, 40,5 por cento; acurácia, 34,12 por cento). CONCLUSÃO: Dados fornecidos pelo ORA (CH e CRF) mostraram-se estatisticamente mais baixos em pacientes com ceratocone quando comparados com córneas finas de indivíduos saudáveis. No entanto, os dois parâmetros biomecânicos estudados apresentaram sensibilidade e especificidade muito baixas na diferenciação dos grupos.


Subject(s)
Adult , Female , Humans , Male , Cornea/physiology , Elastic Tissue/physiology , Elasticity/physiology , Keratoconus/physiopathology , Biomechanical Phenomena , Case-Control Studies , Corneal Topography , Cornea/anatomy & histology , Keratoconus/diagnosis , Keratoconus/pathology , Prospective Studies , ROC Curve , Sensitivity and Specificity
20.
Rev. bras. oftalmol ; 70(1): 11-15, jan.-fev. 2011. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-581587

ABSTRACT

OBJETIVO: Verificar a variação das medidas pressóricas através do Ocular Response Analyzer (ORA, Reichert): IOPg (gold standard, Goldmann correlated intraocular pressure) e IOPcc (corneal compensated intraocular pressure) antes e após a cirurgia de catarata por facoemulsificação. MÉTODOS: Estudo observacional prospectivo envolvendo 47 olhos de 36 pacientes que se submeteram à cirurgia de catarata por facoemulsificação com implante de lente intraocular. A Pressão intraocular compensada da córnea (IOPcc) e correlacionada com Goldmann (IOPg), foram medidos pelo Ocular Response Analyzer (ORA); As medidas foram realizadas no pré-operatório, 1º dia e 30º dia após a cirurgia de facoemulsificação. O Teste de Kolmogorov-Smirnov foi utilizado para avaliar a distribuição normal. Diferenças obtidas entre as medidas obtidas através do Ocular Response Analyzer foram avaliadas pelo T-test (Student's paired t-test). Foi considerado como estatisticamente significante p < 0,05 por cento. RESULTADOS: As médias da IOPcc no pré-operatório, no primeiro dia e no trigésimo dia após a cirurgia de facoemulsificação e implante de LIO foram de 15.6 (±3.06), 15.5 (±3.14) , e 15.71 (±4.34). A média de IOPg no pré-operatório foi de 14.7 (± 3.0), no primeiro dia após cirurgia 12.9 (± 3.1) e no trigésimo dia 13.4 (± 3.7). Houve diferença significativa entre IOPg (PRE X D1) com p < 0,01. CONCLUSÃO: Observamos uma diminuição da IOPg no pós-operatório imediato em córneas com edema após facoemulsificação. Logo, ressaltamos a importância da biomecânica na medida da Pio.


PURPOSE: To evaluate the IOPg (gold standard, Goldmann correlated Intraocular pressure) and IOPcc (corneal compensated Intraocular pressure) in patients prior to and following phacoemulsification with intraocular lens implantation METHODS: This is a prospective study. Thirty six consecutive patients (47 eyes) that underwent phacoemulsification surgery and intraocular lens implantation were enrolled. Full ophthalmologic clinical assessment including Ocular Response Analyzer (ORA, Reichert Ophthalmic Instruments, Buffalo, NY, USA) measurements were performed in all cases prior to surgery (Pre) and at follow-up time points: day 1 and day 30. Exclusion criteria were corneal disease or scars, previous ocular surgery and patients with glaucoma or glaucoma suspect or ocular hypertension. Student's paired t-test was utilized. RESULTS: Mean and standard-deviation of ORA parameters were: IOPcc Pre was 15.6 (±3.06), day 1 (D1) 15.5 (±3.14) and day 30 (D30) 15.71 (±4.34). The mean of IOPg was Pre 14.7 (± 3.0), day 1 (D1) 12.9 (± 3.1), and day 30 (D30) was 13.4 (± 3.7). CONCLUSION: The reduction in the IOPg was observed in the immediate postoperative underestimating the real intraocular pressure ocular. We agree that biomechanical properties may have greater impact on IOP measurements error than corneal tchikness or curvature.


Subject(s)
Humans , Cornea/physiology , Diagnostic Techniques, Ophthalmological , Intraocular Pressure , Lens Implantation, Intraocular , Phacoemulsification , Biomechanical Phenomena , Prospective Studies